CIC
Data Base Inquiry |
|
|
Date of Request:
February 3, 2003 Subject:
Time allowance and labor note
Make:
Honda
Model:
Civic Year:
01-02 Operation:
R&R/R&I radiator and R&R/R&I grille Time
allowance:
Mitchell (grille)
1.2 hrs. R&R and
1.2 hrs. R&I
Labor
text note:
Includes R&I bumper
assembly
Mitchell
(radiator)
.6 hrs. manual and .9 hrs. auto
Labor text note:
with bumper removed
Motor (grille) .3
hrs. R&I and .4 hrs. R&R
Labor
text note:
None
Motor
(radiator)
1.7 hrs manual and 2.0 hrs. auto
Labor
text note:
Includes front bumper R&R or R&I
ADP
Presently not known
CCC
Same as Motor
Labor
text note:
Same as Motor Inquiry
(as suggested by inquirer) Mitchell (radiator): Labor note does not mention the difference in time allowance for vehicles equipped with air conditioning. There is an AC fan to contend with and also the AC condenser must be partially separated to remove radiator. Motor (grille) Insufficient time allowance, please include labor note stating “with bumper
removed.” Motor (radiator) Labor note does not mention the difference in time allowance for vehicles equipped with air conditioning. There is an AC fan to contend with and also the AC condenser must be
partially separated to remove
radiator. Suggestion
To
All: Please review these operations.
Response:
Mitchell: When performing a radiator
support complete R&R, there is an additional time allowed for
the radiator for vehicles with A/C. This is found in the "headnote"
section above the illustration with the refinish times. The
allowance states, add to R&R radiator support with A/C, 0.4hrs.
When performing a radiator R&R stand-alone, the additional time
allowance is located with the part as well.
Motor Information System 10/8/2004 - (ARG4440) Added footnote to grille, “Time is after front bumper is removed.”Changed labor time on radiator to 0.7 hours for manual trans and 0.9 hours for auto trans with footnote, “Time is after front bumper is removed.” and “Time includes R&I cooling fan assembly/shroud.” Added Add if Required operation, R&R radiator , add for AC option 0.2 hours with footnote, “Time is for R&I condenser fan assembly/shroud.” |
|